1 |
Applicable Fiber |
Silica based optical glass fiber: SM,MM,NZDS/G655,EDF,EXF
·Cladding diameter :80 –160um
·Coating diameter :0.1-1.0mm |
Cleave Length |
Standard spec :16mm |
2 |
Splice Loss
(Note 1) |
SM: Typ.0.02Db; MM: Typ.0.01 dB
·Dispersion shifted fiber : Typ.0.04dB |
Splice Time (Note 2) |
Typ. 10 seconds |
heating Time (Note 3) |
40mm/60mm sleeve : Typ.40seconds |
3 |
Dimensions |
160mm(W)/180mm(D)/202mm(H) |
Weight |
3.0 kg |
4 |
Display |
5" LCD,view X and Y axis simultaneously, digital |
5 |
Mode-condition splicing |
SM-FM fiber |
6 |
Battery/Charger |
VFS-20C-01 with battery charge function
·Input: 176~264 V(47~63HZ);·Output: 10.5~15V, 10Ah |
7 |
battery supporting time |
90~100 splicing and heating |
8 |
Proof Test Force |
·Standard spec. : Approx.1.96N(200gf)
·Optional spec. : Approx.4.41N(450gf) |
9 |
Program test |
Atmospheric pressure (max. altitude :3500m),temperature and humidity. Automatic calibration by observing cladding axis offset surface tensions during arc discharge |
Wind Resistance |
Maximum permissible wind velocity: 15m/s |
10 |
Type of Splice Mode |
AUTO,MANUAL |
Fiber magnification |
200 times |
Type of Heater Mode |
60mm, 40mm, 60Ny8, 40Ny8 and micro sleeves |
No. of Heater Modes |
Spot Enactment |
Storage of Splice Results |
8000 |
11 |
splicing time |
9 seconds |